This page (revision-9) was last changed on 03-Feb-2023 15:21 by Stefan Haubenthal 

This page was created on 12-Mar-2010 13:06 by Carsten Strotmann

Only authorized users are allowed to rename pages.

Only authorized users are allowed to delete pages.

Page revision history

Version Date Modified Size Author Changes ... Change note
9 03-Feb-2023 15:21 4 KB Stefan Haubenthal to previous
8 03-Mar-2013 15:36 4 KB Carsten Strotmann to previous | to last
7 03-Mar-2013 15:36 4 KB Carsten Strotmann to previous | to last
6 01-Jan-2011 17:04 4 KB Carsten Strotmann to previous | to last
5 27-Dec-2010 10:09 4 KB Carsten Strotmann to previous | to last
4 12-Mar-2010 13:09 4 KB Carsten Strotmann to previous | to last
3 12-Mar-2010 13:08 3 KB Carsten Strotmann to previous | to last
2 12-Mar-2010 13:07 4 KB Carsten Strotmann to previous | to last
1 12-Mar-2010 13:06 4 KB Carsten Strotmann to last

Page References

Incoming links Outgoing links

Version management

Difference between version and

At line 5 removed 15 lines
!! Disks
* [BiboAssembler/biboass.atr]
* [BiboAssembler/biboasm1.atr]
* [BiboAssembler/biboasm2.atr]
* [BiboAssembler/biboasm3.atr]
* [BiboAssembler/biboass_build003.atr]
!! Source
* [BiboAssembler/bibo_src.zip]
!! Handbook
* [BiboAssembler Handbuch (german)|BiboAssembler/biboass.pdf]
* [BiboAssembler Handbuch (german, HTML)|http://www.hintermueller.de/biboassembler]
At line 38 changed 2 lines
The BiboAssembler Editor is a line Editor with Line-Number, similar to Atari Basic. It can be used like the Atari Basic Editor. Inverse Characters cannot be used except when eclosed in double-quotes. The ASCII Character with Value Zero (the heart in the ATASCI Font) cannot be used. If you need to specify this Char you have to write
{{{ .HX 00 ; Equals ASCII Value Zero }}}
The BiboAssembler Editor is a line Editor with Line-Number, similar to Atari Basic. It can be used like the Atari Basic Editor. Inverse Characters cannot be used except when eclosed in double-quotes. The ASCII Character with Value Zero (the heart in the ATASCI Font) cannot be used. If you need to specify this Char you have to write <p />{{{ .HX 00 ; Equals ASCII Value Zero }}}.
At line 130 removed 5 lines
-----
Martin Metz | 25.01.2009 at 01:04 PM
biboass_build002.atr freshly build from source and installed on XDOS 2.42N. Runs without issues on XDOS 2.42N Has the new pseudo opcode .HS included (SynAss compatible). Build 002 fixes a bug in the "." command of the monitor that is present in build 001 only.